Structural Composition Of Oil Immersed Submersible Pump
Feb 03, 2022| The oil-immersed submersible pump consists of four parts: motor, seal, water pump and control. The water pump and the motor are directly connected coaxially and have a compact structure.
1. Motor part
The motor is located at the lower part of the electric pump and is a three-phase squirrel-cage induction vertical motor. The inner cavity of the motor is filled with No. 5 mechanical oil to facilitate the heat dissipation, cooling and bearing lubrication of the motor windings. The motor is Class B insulation. Bottom cover, oil chamber water inlet and outlet box are made of cast iron, and the power cable used by the motor is YZW type or other types of cables with equivalent performance.
The motor has new ideas in terms of structure. The traditional structure of setting rubber expansion parts in the lower part of the motor cavity to adjust the pressure of the motor cavity is changed, and the oil filling amount of the motor stator cavity is controlled, and a certain cavity is left in the upper part of the motor stator cavity. The structure used to adjust the pressure in the inner cavity of the motor. This new structure is safer and more reliable than the traditional structure. The motor wiring board also adopts the product, which is safer and more reliable than the traditional wiring board.
2. Sealing part
The dynamic seal is located in the oil chamber composed of the water inlet section and the upper end cover at the motor shaft extension. It adopts a double-end unbalanced mechanical seal structure. The first seal module pair adopts cemented carbide, and the second seal module adopts ceramics. The mechanical seal has Good properties such as wear resistance and high temperature resistance, long service life and good sealing effect. The static seal is located at the joint of each part of the electric pump, and adopts "O" type oil-resistant rubber sealing ring.
3. Pump part
The materials used in the water pump parts of various electric pumps of different specifications are cast iron. If the user proposes corrosion resistance requirements, the pump part can be coated with stainless steel or cast iron parts with anti-corrosion and wear-resistant materials, but it needs to be specified in the order that the pump part is located in the motor. The upper part is composed of impeller, guide vane and pump body. For two-stage and multi-stage pumps, each stage adds an impeller, one middle guide vane and one middle pump body. pressure to avoid damage and accidents of the electric pump.
4. Control part
The control part protects the motor parts of the electric pump. Our factory can provide users with corresponding starting control protection cabinets. Motors above 30KW are equipped with an overheat protection switch at the end of the stator winding. When the motor temperature rises too high, the switch will automatically reset. User-configured controls should protect the pump against overload, overheating, phase loss, overvoltage and undervoltage.
Note: The starting method of the control and protection cabinet is auto-coupling step-down starting. The user can choose the matching control equipment of our factory or the control equipment of other units, but it must be able to play an effective protective role.